Magnetic resonance fingerprinting based thermometry (MRFT): application toex vivoimaging near DBS leads
Enlin Qian1,2, Pavan Poojar3, Maggie Fung4
1Columbia Magnetic Resonance Research Center, Columbia University, New York, NY, United States of America.
Abstract:
The purpose of this study is to demonstrate the first work ofT1-based magnetic resonance thermometry using magnetic resonance fingerprinting (dubbed MRFT). We compared temperature estimation of MRFT with proton resonance frequency shift (PRFS) thermometry onex vivobovine muscle. We demonstrated MRFT's feasibility in predicting temperature onex vivobovine muscles with deep brain stimulation (DBS) lead.B0maps generated from MRFT were compared with gold standardB0maps near the DBS lead. MRFT and PRFS estimated temperatures were compared in the presence of motion. All experiments were performed on a 3 Tesla whole-body GE Premier system with a 21-channel receive head coil (GE Healthcare, Milwaukee, WI). Four fluoroptic probes were used to measure the temperature at the center of a cold muscle (probe 1), the room temperature water bottle (probe 2), and the center and periphery of the heated muscle (probes 3 and 4). We selected regions of interest (ROIs) around the location of the probes and used simple linear regression to generate the temperature sensitivity calibration equations that convertT1maps and Δsmaps to temperature maps. We then repeated the same setup and compared MRFT and PRFS thermometry temperature estimation with gold standard probe measurements. For the MRFT experiment on DBS lead, we taped the probe to the tip of the DBS lead and used a turbo spin echo sequence to induce heating near the lead. We selected ROIs around the tip of the lead to compare MRFT temperature estimation with probe measurements and compared with PRFS temperature estimation. Vendor-suppliedB0mapping sequence was acquired to compare with MRFT-generatedB0maps. We found strong linear relationships (R2> 0.958) betweenT1and temperature and Δsand temperatures in our temperature sensitivity calibration experiment. MRFT and PRFS thermometry both accurately predict temperature (RMSE < 1.55 °C) compared to probe measurements. MRFT estimated temperature near DBS lead has a similar trend as the probe temperature. BothB0maps show inhomogeneities around the lead. MRFT estimated temperature is less sensitive to motion.
More Related Videos
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
10:09Mapping the After-effects of Theta Burst Stimulation on the Human Auditory Cortex with Functional Imaging
Published on: September 12, 2012
Related Concept Videos
Magnetic Resonance Imaging
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...