Global constructive work is associated with ventricular arrhythmias after cardiac resynchronization therapy
Hillah Saffi1, Ulrik Winsløw1, Tharsika Sakthivel1
1Department of Cardiology, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.
Aims:
Non-invasive left ventricular (LV) pressure-strain loops provide a novel method for quantifying myocardial work by incorporating LV pressure in measurements of myocardial deformation. Early studies suggest that myocardial work parameters such as global constructive work (GCW) could be useful and reliable in arrhythmia prediction, particularly in patients undergoing cardiac resynchronization therapy (CRT). The aim of this study was to evaluate whether the magnitude of GCW was associated with the occurrence of ventricular arrhythmias in patients after CRT.
Methods And Results:
Patients on guideline-recommended treatment with a CRT defibrillator (CRT-D) were evaluated by 2D speckle-tracking echocardiography including measurements of GCW at least 6 months after implantation. The primary outcome was a composite of appropriate defibrillator therapy and sustained ventricular arrhythmia under the monitor zone. A total of 162 patients [mean age 66 years (±10), 122 males (75%)] were included. Sixteen (10%) patients experienced the primary outcome during a median follow-up of 18 months (interquartile range: 12-25) after the performance of index echocardiography. Patients with a below-median GCW (<1473 mmHg%) had a hazard ratio (HR) for the outcome of 8.14 [95% confidence interval (CI): 1.83-36.08], P = 0.006 compared with patients above the median in a univariate model and remained an independent predictor after multivariate adjustment for the estimated glomerular filtration rate and QRS duration [HR 4.75 (95% CI: 1.01-22.28), P < 0.05].
Conclusion:
In patients treated with CRT-D, a GCW below median level was associated with a five-fold increase in the risk of ventricular arrhythmias.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Mechanism of Cardiac Arrhythmias
Dysrhythmias VI: Management of Dysrhythmias
Electrophysiology of Normal Cardiac Rhythm
Cardiomyopathy II: Dilated Cardiomyopathy