Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Effect of assessing velocity time integral at different locations across ventricular outflow tracts when calculating
Jane Huang1, Yogen Singh2,3, Mohammad Adie2
1Division of Neonatology, Department of Pediatrics, LAC+USC Medical Center, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA. janehuang@chla.usc.edu.
Abstract:
This study aims to evaluate the effect of assessing velocity time integral at different locations across ventricular outflow tracts for calculating cardiac output (CO) in neonates. Velocity time integral (VTI) and CO were measured at 3 different locations across right and left ventricular outflow tracts using transthoracic echocardiography in healthy term neonates without any major congenital heart disease. ANOVA with Bonferroni correction was used to determine the differences between the VTI and CO sampled at these three locations. Forty-one neonates met inclusion criteria with mean gestational age of 38.6 ± 1 weeks and mean birth weight of 3155 ± 463 g. The median hours after birth when echocardiography was obtained was 23 h (range 11-68 h after birth). Left CO were 121 ± 30 mL/kg/min, 155 ± 38 mL/kg/min, and 176 ± 36 mL/kg/min measured below the valve, hinges of the valve, and tip of the valve, respectively. Right CO were 197 ± 73 mL/kg/min, 270 ± 83 mL/kg/min, and 329 ± 104 mL/kg/min measured below the valve, hinges of the valve, and tip of the valve, respectively. A statistically significant difference (P < 0.001) was found in the VTI and CO measured at the 3 different locations across both left and right ventricular outflow tracts. Conclusions: There is a significant difference in measurements of VTI and CO depending on the location of Doppler gate sampling across the ventricular outflow tracts. Consistency and precision in Doppler gate location are essential for measuring VTI and calculating CO while assessing changes in hemodynamic status in critically ill infants. What is Known: • Targeted Neonatal Echocardiography is increasingly applied to measure cardiac output in critically ill neonates and serial assessments are performed to assess the trend in changes in cardiac output. • Noninvasive measurement using velocity time integral to calculate cardiac output is commonly performed. However, location of Doppler sample gate to measure ventricular outflow tract velocity time integral is not consistent. What is New: • Statistically significant changes in measured velocity time integral and cardiac output are noted based on the location of Doppler gate sampling. • To monitor the cardiac output for trending, it is important to be consistent with regards to the location of the Doppler sample gate to assess changes in cardiac output in critically ill newborns.
More Related Videos
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Velocity and Position by Graphical Method