Related Experiment Video
Updated: Jul 21, 2025

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Differences in joint line level and posterior condylar offset during total knee replacement with use of gap-balancing
Bartosz M Maciąg1, Tomasz Kordyaczny2, Dawid Jegierski2
1Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Międzyleski Specialist Hospital, Str. 2 Bursztynowa, 04-749, Warsaw, Poland. bmaciag@wum.edu.pl.
Background:
Total knee replacement (TKR) is considered one of the most common elective orthopaedic procedures. The main focus of TKR is to offer patient's symptomatic relief from persistent knee pain. To achieve this it is crucial to restore joint biomechanics by performing proper bone cuts. Some surgeons favor the measured resection technique, others prefer gap balancing technique. The researchers of the presented study performed TKR using these two techniques. The aim of this study was to compare the postoperative change in joint line and posterior condylar offset after TKR with use of anatomic knee design implants between gap balancing and measured resection techniques.
Methods:
Two hundred twenty-five X-rays of patients who underwent TKR performed by a single surgeon between 2020 and 2021 were analyzed. The first group of patients (101) was operated with the use of gap balancing technique and the second group (124) was operated with the use of measured resection technique. Patients included in the study were > 50 years of age, had confirmed primary knee osteoarthritis, underwent primary TKR with a PS (posterior stabilized) knee implants without patella resurfacing and had at least 15 degree flexion contracture. T-student test and U Mann-Whitney test were used in statistical analysis of results, according to the normality of distribution examined with the Shapiro-Wilk test. Post-hoc analysis was performed using the Dwass-Steel-Crichtlow-Fligner test (DSCF).
Results:
The postoperative analysis showed a significantly elevated joint line level in the gap balancing group (-2.6 ± 4.1 vs -0.7 ± 4.8, p < 0.0005). In the gap balancing group significantly more patients had joint lines elevated > 2 mm comparing to measured resection technique. The difference between pre- and postoperative PCO (posterior condylar offset) and PCOR (posterior condylar offset ratio) results had no significant differences (100.8 ± 11.8 vs 101 ± 12.5, p > 0.05) between the groups.
Conclusions:
The results of the study suggest that when it comes to restoring joint line level measured resection technique seems to be superior in comparison to the gap balancing technique. What is more, results indicate measured resection is equal in terms of restoring posterior condylar offset to the gap balancing technique.
Trial Registration:
NCT04164147, date of registration: November 14, 2019.