Related Experiment Video
Updated: Jul 21, 2025

Multi-Stream Perfusion Bioreactor Integrated with Outlet Fractionation for Dynamic Cell Culture
Published on: July 20, 2022
Flow rate accuracy of infusion devices within healthcare settings: a systematic review
Opeyemi Atanda1, Jonathan West2, Tom Stables2
1Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, St. Mary Campus, QEQM Building, London, SW7 2AZ, UK.
Background:
One in five patients admitted to the hospital treated with intravenous (IV) fluid therapy suffer complications due to inappropriate administration. Errors have been reported in 13-84% of the preparation and administration of IV medications. The safe delivery of IV fluids requires precise rate administration.
Objectives:
This systematic review aims to determine the accuracy of infusion sets and devices and examine the factors that affect the flow rate accuracy of devices.
Data Sources And Methods:
Six databases (CINAHL, MEDLINE PubMed, EMBASE, Web of Science and Cochrane Database of systematic reviews) were systematically searched. Search terms included infusion pumps, infusion devices, flow rate accuracy, fluid administration rate, gravity-led infusion set and fluid balance. Studies were included if they examined infusion devices' flow rate accuracy and drop rates for fluids or non-oncological drugs. Findings were tabulated and synthesised qualitatively. The quality of the studies was examined based on the design of the studies due to their heterogeneity.
Results:
Eight studies were included: Four studies were conducted on human subjects in the hospital environment; studies recruited 182 participants between the ages of 18 and 94 years. Two studies examined flow rate accuracy in recruited patients across 509 observations and 2387 drip hours. No trials prospectively assessed the accuracy of infusion pumps in the clinical domain, and no studies were reported on patient safety outcomes. Four studies examined the impact of mechanical and physiological factors on the flow rate accuracies of infusion devices. Height and back pressure simulated vibrating conditions, the viscosity of IV fluid and the positions of patients were reported to have a significant impact on infusion volume and flow rates of infusion devices. Additionally, giving sets that vary from the manufacturer's specifications are reported to increase error percent by 10-20%.
Conclusion:
Infusion devices are an important source of error in administering IV fluids. Yet, there needs to be more prospective trial data to support their clinical accuracy and the impact on patient outcomes. Future flow variability and accuracy studies should capture their impact on patient safety and clinical outcomes.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Errors occurring during blood pressure monitoring
Several factors...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Uncertainty in Measurement: Accuracy and Precision
Flow Sheet
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation: