Related Experiment Video
Updated: Jul 21, 2025

Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Suppressor and calibration standard limitations in cation chromatography of ammonium and 10 alkylamines in
Leyla Salehpoor1, Trevor C VandenBoer1
1Department of Chemistry, York University, Toronto, ON, Canada. tvandenb@yorku.ca.
Abstract:
Ammonia (NH3) and alkylamines are ubiquitous in the atmosphere and have been suggested to play important global roles through new particle formation and aerosol growth. In this work, we optimized an ion-chromatographic (IC) method to separate and quantify the ten most abundant atmospheric alkylamines with high selectivity and separation efficiency, using 4 μm packed columns and resin-based suppressors, alongside stabilizing amine standards. Modern resin suppressors operating on a gradient elution program affected the linear response of this IC technique. Calibration statistical analyses found a loss of analytes in these cation-exchange devices. Suppressor operational longevity was optimized by using a stepped current and an external water supply, which improved precision, accuracy, and LODs compared to other suppression modes. When this new method was applied to real samples, amines were found ubiquitously in size-resolved marine aerosol samples; monopropylamine, isomonopropylamine, and monobutylamine were detected and quantified, which have not been reported before. The molar ratio of the sum of aminium to ammonium ranged from 0.02 to 0.2, showcasing the application of the developed method towards studying the diversity and importance of alkylamines in coastal marine particle composition. The new analytical method also found NH3 present in a suite of new homes with a mean mixing ratio of 25 ± 15 ppbv; a common level reached between homes across the study during the first year of occupation which can then be transported outdoors.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
08:05Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
NMR Spectroscopy Of Amines
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry of Amines
Amines undergo fragmentation through α cleavage, producing nitrogen-containing cations—iminium ions—and alkyl radicals. Mass spectra of aromatic and cyclic aliphatic amines exhibit...
Basicity of Aliphatic Amines
To measure the basicity of amines, two conventions are generally used. The first defines Kb as the basicity constant for the deprotonation reaction of water by the amine, as presented in Figure 1. Conventionally, lower Kb indicates...