Prediction model of transformer top oil temperature based on data quality enhancement
Naxin Dong1, Ruoyu Zhang2, Zong Li2
1Faculty of Computer Science and Information Technology, University of Malaya, Kuala Lumpur 50603, Malaysia.
Abstract:
Top oil temperature (TOT) is an important parameter to evaluate the running state of a transformer. According to the variation trend of TOT, the internal thermal state of transformers can be predicted so as to arrange operation and maintenance reasonably and prevent the occurrence of accidents. However, due to the complex working environment in the field, there are often a large number of missing values in online monitoring data, which seriously affects the prediction of TOT. At the same time, it is affected by various factors such as load, ambient temperature, wind speed, and solar radiation, which cause the information of different time scales to be mixed in its monitoring data. Therefore, it is difficult to achieve the desired accuracy with a single model. In this article, a model for predicting TOT based on data quality enhancement is proposed. First, the Markov model is used to complete the online monitoring data containing missing values to obtain a complete and continuous time series. Then, using the ensemble empirical modal decomposition method, the time series of TOT is decomposed into multiple time series components to eliminate the interaction between different time scales of information, thus reducing the prediction difficulty. Finally, the sub-prediction model of the extreme learning machine is constructed, and the prediction results of all the sub-models are reconstructed to obtain the final prediction results of TOT. In order to verify the effectiveness of the model, the TOT of an operating transformer for the next two days is predicted in the article, and its mean absolute percentage error (MAPE) is 5.27% and its root mean square error (RMSE) is 2.46. Compared with the BP neural network model and the support vector machines (SVM) model, the MAPE is reduced by 69.56% and 61.92%, respectively, and the RMSE is reduced by 67.02% and 59.87%. The results of this study will provide important support for the fault diagnosis of the top oil temperature online monitoring system.
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Transformers with Off-Nominal Turns Ratios
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...