Related Experiment Video
Updated: Jul 21, 2025

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Comparison of corneal tomographic parameters between Hispanic and non-Hispanic patients
So Yeon Uhm1, Trong Phat Do1, Rafael Heinz Montoya1
1Department of Ophthalmology, UT Health San Antonio, San Antonio, TX, USA.
Purpose:
To compare corneal tomographic parameters between Hispanic White and non-Hispanic White patients using Pentacam data.
Methods:
This retrospective study evaluated preoperative Pentacam data from 641 patients 50 years or older who underwent surgery for senile cataract and self-identified as Hispanic or non-Hispanic White. Patients of non-White race or multiethnic groups, or a history of surgery, trauma, or any abnormality of the cornea or anterior segment were excluded. Cornea and anterior segment parameters, as measured with Pentacam, were then compared between Hispanics and non-Hispanics.
Results:
There were 352 Hispanic White and 289 non-Hispanic White patients. These included 231 men and 410 women, with a mean age of 69.5 ± 8.2 years. There were no significant differences between Hispanics and non-Hispanics in front or back keratometry or amount of front astigmatism. However, Hispanics had a greater amount of back astigmatism (0.36 ± 0.19 vs 0.32 ± 0.17 diopter, P = 0.04). Moreover, there was a statistically significant difference in front steep axis of the left eyes between Hispanics and non-Hispanics (97.8 ± 47.9 vs 108.2 ± 48.9 deg, P = 0.01), and a marginally significant difference in front steep axis of the right eyes (81.0 ± 48.2 vs 73.5 ± 49.9 deg, P = 0.06). Hispanics also had a lower vertex pachymetry (548.1 ± 34.5 vs 553.4 ± 37.4 μm, P = 0.04) and a smaller anterior chamber volume (134.7 ± 39.0 vs 146.1 ± 39.9 mm3, P < 0.001).
Conclusions:
There are some differences in cornea and anterior segment parameters between Hispanics and non-Hispanics 50 years or older who underwent surgery for senile cataract. However, such differences may not be clinically significant.
More Related Videos
11:29Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
Published on: January 3, 2011
03:35Determining Gender-Based Differences in Retinal and Choroidal Thickness in Underweight Individuals via Swept-Source Optical Coherence Tomography
Published on: December 1, 2023
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...