Oxygenation Instability during Bolus versus Continuous Feeding among Very Low Birth Weight Premature Infants,
Liron Borenstein-Levin1,2, Ahmad Haj1,2, Arieh Riskin2,3
1Neonatal Intensive Care Unit, Ruth Rappaport Children's Hospital, Rambam Health Care Campus, Haifa, Israel.
Objective:
This study aimed to compare oxygenation instability, as documented by the oxygen saturation (SpO2) histograms, during bolus (over 30 minutes) versus continuous (over 2 hours) feeding among very low birth weight (VLBW) premature infants, supported with noninvasive ventilation (NIV).
Study Design:
This was a randomized prospective study. VLBW infants supported with NIV received three consecutive feeds in a random order of bolus-continuous-bolus or continuous-bolus-continuous. During each feed, 30 minutes and 2 hours histograms were documented.
Results:
Twenty-four infants (birth weight [mean ± standard deviation, SD] 820 ± 168 g, gestational age [mean ± SD] 27.0 ± 1.6 weeks) were included in our study (12 infants started with bolus feeding and 12 with continuous feeding) and 72 histograms were obtained (36 during bolus feeding and 36 during continuous feeding). No differences in mean fraction of inspired oxygen (FiO2), and number of apnea events were observed between the two feeding modes. Oxygenation instability as assessed by time spent in different SpO2 ranges and histogram types (stable or unstable) was comparable during bolus and continuous feedings. Changing feeding mode from bolus to continuous or vice versa did not significantly change the oxygenation instability of the group, though individual infants did show a consistence response to feeding length changes.
Conclusion:
Among VLBW infants supported with NIV, oxygenation instability, as documented by SpO2 histograms, was comparable between bolus and continuous feedings. Individual infants may benefit from specific feeding length, and this can be easily demonstrated by the SpO2 histograms.
Key Points:
· Feeding length did not affect oxygenation instability of preterm infants on noninvasive respiratory Support.. · Oxygen saturation histograms allow objective quantification of oxygenation instability at the bedside.. · Individual infants benefit from specific feeding length, as demonstrated by SpO2 histograms..
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Mechanical Ventilation I: Indication and Settings