Purpose:
Peak tibial acceleration (PTA) is defined as the peak acceleration occurring shortly after initial contact, often used as an indirect measure of tibial load. As the tibia is a rotating segment around the ankle, angular velocity and angular acceleration should be included in PTA. This study aimed to quantify three-dimensional tibial acceleration components over two different sensor locations and three running speeds, to get a better understanding of the influence of centripetal and tangential accelerations on PTA typically measured in running. Furthermore, it explores tibial impulse as an alternative surrogate measure for tibial load.
Methods:
Fifteen participants ran 90 s on a treadmill at 2.8, 3.3, and 3.9 m·s -1 , with inertial measurement units (IMUs) located distally and proximally on the tibia.
Results:
Without the inclusion of rotational accelerations and gravity, no significant difference was found between axial PTA between both IMU locations, whereas in the tangential sagittal plane axis, there was a significant difference. Inclusion of rotational accelerations and gravity resulted in similar PTA estimates at the ankle for both IMU locations and caused a significant difference between PTA based on the distal IMU and PTA at the ankle. The impulse showed more consistent results between the proximal and distal IMU locations compared with axial PTA.
Conclusions:
Rotational acceleration of the tibia during stance differently impacted PTA measured proximally and distally at the tibia, indicating that rotational acceleration and gravity should be included in PTA estimates. Furthermore, peak acceleration values (such as PTA) are not always reliable when using IMUs because of inconsistent PTA proximally compared with distally on an individual level. Instead, impulse seems to be a more consistent surrogate measure for the tibial load.
Related Concept Videos
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Relative Motion Analysis - Acceleration
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...