Related Experiment Video
Updated: Jul 21, 2025

Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Brady-arrhythmias requiring permanent pacemaker implantation during and after staged Fontan palliation
Cornelius Bohn1,2, Thibault Schaeffer1,2, Helena Staehler1,2
1Department of Congenital and Pediatric Heart Surgery, German Heart Center Munich, Technische Universität, Munich, Germany.
Background:
Brady-arrhythmia requiring pacemaker implantation remains one of the Fontan-specific complications before and after total cavopulmonary connection.
Methods:
A retrospective analysis of 620 patients who underwent total cavopulmonary connection between 1994 and 2021 was performed to evaluate the incidence of brady-arrhythmia and the outcomes after pacemaker implantation. Factors associated with the onset of brady-arrhythmia were identified.
Results:
A total of 52 patients presented with brady-arrhythmia and required pacemaker implantation. Diagnosis included 16 sinus node dysfunctions, 29 atrioventricular blocks, and 7 junctional escape rhythms. Pacemaker implantation was performed before total cavopulmonary connection (n = 16), concomitant with total cavopulmonary connection (n = 8), or after total cavopulmonary connection (n = 28, median 1.8 years post-operatively). Freedom from pacemaker implantation following total cavopulmonary connection at 10 years was 92%. Twelve patients needed revision of electrodes due to lead dysfunction (n = 9), infections (n = 2), or dislocation (n = 1). Lead energy thresholds were stable, and freedom from pacemaker lead revision at 10 years after total cavopulmonary connection was 78%. Congenitally corrected transposition of the great arteries (odds ratio: 6.6, confidence interval: 2.0-21.5, p = 0.002) was identified as a factor associated with pacemaker implantation before total cavopulmonary connection. Pacemaker rhythms for Fontan circulation were not a risk factor for survival (p = 0.226), protein-losing enteropathy/plastic bronchitis (p = 0.973), or thromboembolic complications (p = 0.424).
Conclusions:
In our cohort of patients following total cavopulmonary connection, freedom from pacemaker implantation at 10 years was 92% and stable atrial and ventricular lead energy thresholds were observed. Congenitally corrected transposition of the great arteries was at increased risk for pacemaker implantation before total cavopulmonary connection. Having a pacemaker in the Fontan circulation had no adverse effect on survival, protein-losing enteropathy/plastic bronchitis, or thromboembolic complications.
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Heart Failure VI: Adjunct Therapies
Mechanism of Cardiac Arrhythmias