Related Experiment Video
Updated: Jul 11, 2026
![Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F50301.jpg&w=3840&q=50)
Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
Assessment of orocoecal transit time by means of a hydrogen (H2) breath test as compared with a radiologic control
Abstract:
The definition of the orocoecal transit time by means of the hydrogen (H2) breath test is not unequivocal. In this study the orocoecal transit time as measured with an H2 breath test was compared with that obtained with a radiologic method. Two definitions of orocoecal transit time by the H2 breath test were evaluated: the time from eating to the first of three consecutively rising H2 values, and the interval to H2 values 50% above 'small-bowel level'. Transit times measured in accordance with both definitions were closely correlated to that obtained with the radiologic method (A, r = 0.84; B, r = 0.90; for both, p less than 0.001), but transit time measured by definition A gave shorter values than the radiologic method (p less than 0.05). The mean transit time in patients with constipation was significantly longer than that in normal subjects and patients with functional diarrhoea (p less than 0.05). There was a significant correlation between the difference in transit time measured with the H2 breath test and the radiologic method and the transit time measured by the control method. This may indicate that rapid transit is associated with a delayed 'colonic' rise in H2 levels and slow transit with an early H2 rise.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
08:44Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Serum Laboratory Studies, Stool Test, Breath Test
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...