Ion-to-Image, i2i, a Mass Spectrometry Imaging Data Analysis Platform for Continuous Ionization Techniques.
Johan Lillja1, Kyle D Duncan1,2, Ingela Lanekoff1
1Department of Chemistry - BMC, Uppsala University, Uppsala, 752 37, Sweden.
Analytical Chemistry
|July 28, 2023
Summary
A new MATLAB application, ion-to-image (i2i), simplifies processing of mass spectrometry imaging (MSI) data from continuous ionization sources. This tool handles complex datasets, enabling faster and more flexible ion image generation for researchers.
Area of Science:
- Analytical Chemistry
- Biotechnology
- Computational Chemistry
Background:
- Mass spectrometry imaging (MSI) provides high-sensitivity, selective molecular distribution data.
- Processing MSI data, especially from continuous ionization sources with automatic gain control (AGC), presents significant challenges.
- Existing software often lacks specialized handling for continuous ionization MSI data, necessitating new solutions.
Purpose of the Study:
- To introduce ion-to-image (i2i), a novel MATLAB-based application for processing MSI data.
- To address the specific data handling needs of continuous ionization sources, AGC, and high-resolution datasets.
- To offer a flexible and efficient tool for generating, processing, and exporting ion images from complex MSI data.
Main Methods:
- Development of a MATLAB-based application named ion-to-image (i2i).
- Implementation of quantitative, targeted, and nontargeted data processing strategies.
- Support for complex scan functions, including MSⁿ and SIM data, alongside full scans.
Main Results:
- i2i enables rapid processing of large and complex MSI datasets, reducing processing time to minutes.
- The application facilitates the generation of ion images from MSI data acquired with continuous ionization sources and AGC.
- Provides flexibility in data processing and export options for various MSI applications.
Conclusions:
- i2i offers a valuable, flexible, and efficient solution for handling specialized MSI data.
- The developed software addresses a critical gap in MSI data processing tools.
- i2i is expected to become a significant asset in the MSI software landscape.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
800
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
800
Chemical Ionization (CI) Mass Spectrometry
801
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
801
MALDI-TOF Mass Spectrometry
4.9K
Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
4.9K
Mass Spectrometers
5.7K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
5.7K
Ion-Exchange Chromatography
585
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
585
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
519
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
519


