Velocity Time Integral: A Novel Method for Assessing Fetal Anemia.
Ettie Piura1,2, Offra Engel1,2, Neta Doctory2
1Department of Obstetrics and Gynecology, Meir Medical Center, Kfar Saba 4428164, Israel.
Children (Basel, Switzerland)
|July 29, 2023
Summary
The velocity time integral (VTI) in fetal middle cerebral artery (MCA) blood flow increases with suspected anemia. This Doppler ultrasound measurement may serve as a novel marker for fetal anemia detection.
Area of Science:
- Perinatology
- Fetal Medicine
- Diagnostic Ultrasound
Background:
- Maternal alloimmunization poses risks to fetal well-being.
- Doppler ultrasound is crucial for assessing fetal circulation.
- Middle cerebral artery (MCA) peak systolic velocity (PSV) is a key indicator of fetal anemia.
Purpose of the Study:
- To evaluate the velocity time integral (VTI) in the MCA of fetuses with and without suspected anemia due to maternal alloimmunization.
- To determine if MCA VTI can serve as an additional marker for fetal anemia.
Main Methods:
- Retrospective analysis of 255 fetal Doppler ultrasound examinations from 16-40 weeks gestation.
- Measurement of MCA VTI, systolic deceleration-diastolic time, systolic acceleration time, and PSV.
- Comparison of VTI in fetuses with MCA-PSV ≥ 1.5 MoM (suspected anemia) versus MCA-PSV < 1.5 MoM (normal).
Main Results:
- MCA VTI demonstrated a significant increase throughout gestation (p = 0.003).
- Fetuses with suspected anemia (MCA-PSV ≥ 1.5 MoM) exhibited significantly higher VTI compared to those without (14.1 cm vs. 9.1 cm, p < 0.001).
- VTI/s was also significantly higher in fetuses with suspected anemia (33.75 cm/s vs. 22.04 cm/s, p < 0.001).
Conclusions:
- MCA VTI significantly increases in fetuses with suspected anemia, suggesting increased cerebral blood flow.
- Elevated MCA VTI may indicate higher perfusion of hemodiluted blood to the brain in anemic fetuses.
- MCA VTI is a feasible measurement and a potential novel marker for the development of fetal anemia.