Inconsistency in Shoulder Arthrometers for Measuring Glenohumeral Joint Laxity: A Systematic Review
Eluana Gomes1, Renato Andrade1,2,3, Cristina Valente1,2
1Clínica Espregueira-FIFA Medical Centre of Excellence, 4350-415 Porto, Portugal.
Abstract:
There is no consensus on how to measure shoulder joint laxity and results reported in the literature are not well systematized for the available shoulder arthrometer devices. This systematic review aims to summarize the results of currently available shoulder arthrometers for measuring glenohumeral laxity in individuals with healthy or injured shoulders. Searches were conducted on the PubMed, EMBASE, and Web of Science databases to identify studies that measure glenohumeral laxity with arthrometer-assisted assessment. The mean and standard deviations of the laxity measurement from each study were compared based on the type of population and arthrometer used. Data were organized according to the testing characteristics. A total of 23 studies were included and comprised 1162 shoulders. Populations were divided into 401 healthy individuals, 278 athletes with asymptomatic shoulder, and 134 individuals with symptomatic shoulder. Sensors were the most used method for measuring glenohumeral laxity and stiffness. Most arthrometers applied an external force to the humeral head or superior humerus by a manual-assisted mechanism. Glenohumeral laxity and stiffness were mostly assessed in the sagittal plane. There is substantial heterogeneity in glenohumeral laxity values that is mostly related to the arthrometer used and the testing conditions. This variability can lead to inconsistent results and influence the diagnosis and treatment decision-making.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure in the Leg
Preparation:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection