A Comparative Analysis of Morphology and Dimensions of Functional Blebs following PRESERFLO-Microshunt and
Somar M Hasan1, Theresa Theilig1, Menelaos Papadimitriou1
1Department of Ophthalmology, Jena University Hospital, 07747 Jena, Germany.
Abstract:
Evaluation of bleb morphology is a vital part of successful filtration glaucoma surgery. The PRESERFLO-MicroShunt (PRESERFLO) and XEN-Gel-Stent (XEN) are drainage devices implanted using different surgical approaches (ab externo and ab interno, respectively), potentially resulting in distinct bleb morphology. Understanding these morphological differences is essential for postoperative care. In this study, we retrospectively examined functioning blebs following PRESERFLO and XEN implantation using high-resolution anterior segment OCT imaging. Qualitative assessment utilizing the Jenaer Bleb Grading System and quantitative assessment measuring 12 parameters representing bleb dimensions were conducted, and the results were compared between the two groups. A total of 80 eyes from 80 patients were included (41 after PRESERFLO, 39 after XEN). Functioning blebs following PRESERFLO exhibited a higher frequency of hyperreflective tenon changes compared to XEN (31.7% vs. 10.3%, respectively, p = 0.02) and a lower frequency of cavernous changes (17.1% vs. 35.9%, p = 0.05). Additionally, PRESERFLO blebs showed a higher frequency of visible episcleral lakes (92.7% vs. 30.8%, p < 0.001). Furthermore, PRESERFLO blebs demonstrated larger height (2.13 ± 0.5 vs. 1.85 ± 0.6 mm, p = 0.03), width (10.31 ± 2.3 vs. 9.1 ± 2.3 mm, p = 0.02), length (9.13 ± 1.8 vs. 8.24 ± 1.9 mm, p = 0.04), posterior location relative to the limbus (6.21 ± 1.2 vs. 5.21 ± 1.8 mm, p = 0.005), and a thicker bleb wall (1.60 ± 0.5 vs. 1.1 ± 0.4 mm, p = 0.004). Functioning blebs following PRESERFLO and XEN displayed morphological distinctions, likely attributed to variations in surgical techniques (ab externo vs. ab interno) and stent dimensions. These morphological differences should be taken into consideration when evaluating blebs, as they could impact assessments of bleb functionality and influence decisions regarding postoperative interventions.
More Related Videos
07:13An Alternative and Validated Injection Method for Accessing the Subretinal Space via a Transcleral Posterior Approach
Published on: December 7, 2016
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018