Related Experiment Video
Updated: Jul 21, 2025

Rat Model of Adhesive Capsulitis of the Shoulder
Published on: September 28, 2018
Objective Assessment of Syndesmosis Stability Using the Hook Test
Jakob Hallbauer1, Philipp Schenk2,3, Lea Herrmann1
1Department of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Friedrich Schiller University Jena, 07747 Jena, Germany.
The hook test for syndesmosis stability assessment shows high variability in practice and cannot reliably detect injuries, even when standardized. Further research is needed to improve intraoperative diagnostic accuracy.
Area of Science:
- Orthopedic Surgery
- Biomechanics
- Surgical Assessment
Background:
- The hook test is a common intraoperative method for evaluating syndesmosis stability.
- Current guidelines lack specific force recommendations for the hook test.
- The reliability of the hook test in clinical practice remains uncertain.
Purpose of the Study:
- To investigate the forces applied during the hook test by experienced surgeons.
- To assess the reliability and diagnostic accuracy of the hook test under standardized conditions.
- To determine the influence of applied force and syndesmotic instability on diastasis measurement.
Main Methods:
- Ten experienced surgeons performed hook tests on cadaver models, with forces recorded.
- Standardized hook tests with defined forces (50, 80, 100 N) were conducted on cadaver lower legs with sequential destabilization.
- Syndesmotic diastasis was measured using an optical 3D camera system.
Main Results:
- Surgeons applied a median force of 81 N (Range: 50-145 N), with 82% of tests below 100 N.
- The study found good intra-rater reliability but poor inter-rater reliability.
- Even with maximum instability, diastasis > 2 mm was measured in only 12 of 19 specimens, indicating low sensitivity.
Conclusions:
- The hook test demonstrates significant variability in clinical application.
- Standardized application of the hook test is insufficient to reliably detect relevant syndesmotic injuries.
- The findings suggest limitations in the hook test's ability to accurately diagnose syndesmotic instability intraoperatively.
Related Concept Videos
Stability of structures
Applications of Stress
The...
Method of Joints: Problem Solving II
Structural Joints: Fibrous Joints
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...
Ankle Joint
Method of Joints: Problem Solving I