RisCO2: Implementation and Performance Evaluation of RISC-V Processors for Low-Power CO2 Concentration Sensing.

Ricardo Núñez-Prieto1,2, David Castells-Rufas1,2, Lluís Terés-Terés2,3

  • 1Barcelona Supercomputing Center (BSC), 08034 Barcelona, Spain.

Micromachines
|July 29, 2023
PubMed
Summary

A new RISC-5 processor, RisCO2, offers superior energy efficiency for embedded systems. Optimized for nondispersive infrared (NDIR) CO2 sensors, RisCO2 significantly reduces power consumption and resource utilization in signal processing applications.

Related Concept Videos

Semiconductors01:22

Semiconductors

There is variation in the electrical conductivity of materials - metals, semiconductors, and insulators that are showcased with the help of the energy band diagrams.
Metals such as copper (Cu), zinc (Zn), or lead (Pb) have low resistivity and feature conduction bands that are either not fully occupied or overlap with the valence band, making a bandgap non-existent. This allows electrons in the highest energy levels of the valence band to easily transition to the conduction band upon gaining...
745
Non-ohmic Devices00:51

Non-ohmic Devices

In most substances, the current flow is proportional to the voltage applied to it. A simple relationship between the values of current, voltage, and resistance is known as Ohm's law. Nonohmic devices do not exhibit a linear relationship between voltage and current. One such device is the semiconducting circuit element known as a diode. A diode is a circuit device that allows current flow in only one direction.
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
1.1K
PI Controller: Design01:24

PI Controller: Design

Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
331
Constant Pressure Calorimetry03:02

Constant Pressure Calorimetry

Calorimetry is a technique used to measure the amount of heat involved in a chemical or physical process or to measure the heat transferred to or from a substance. The heat is exchanged with a calibrated and insulated device called the calorimeter. Calorimetry experiments are based on the assumption that there is no heat exchange between the insulated calorimeter and the external environment. The well-insulated calorimeters prevent the transfer of heat between the calorimeter and its external...
85.5K
Assessment of Respiration01:23

Assessment of Respiration

The respiratory system's basic structures and primary functions lay the foundation for nurses' comprehensive respiratory assessments. This assessment includes subjective and objective data to gauge the patient's respiratory health.
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
1.2K