Related Experiment Video
Updated: Jul 20, 2025

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Evaluation of Correlation between Temperature of IoT Microcontroller Devices and Blockchain Energy Consumption in
Kithmini Godewatte Arachchige1, Philip Branch1, Jason But1
1Department of Telecommunications, Electrical, Robotics and Biomedical Engineering, Swinburne University, Melbourne 3122, Australia.
Abstract:
Blockchain technology is an information security solution that operates on a distributed ledger system. Blockchain technology has considerable potential for securing Internet of Things (IoT) low-powered devices. However, the integration of IoT and blockchain technologies raises a number of research issues. One of the most important is the energy consumption of different blockchain algorithms. Because IoT devices are typically low-powered battery-powered devices, the energy consumption of any blockchain node must be kept low. IoT end nodes are typically low-powered devices expected to survive for extended periods without battery replacement. Energy consumption of blockchain algorithms is an important consideration in any application that combines both technologies, as some blockchain algorithms are infeasible because they consume large amounts of energy, causing the IoT device to reach high temperatures and potentially damaging the hardware; they are also a possible fire hazard. In this paper, we examine the temperatures reached in devices used to process blockchain algorithms, and the energy consumption of three commonly used blockchain algorithms running on low-powered microcontrollers communicating in a wireless sensor network. We found temperatures of IoT devices and energy consumption were highly correlated with the temperatures reached. The results indicate that device temperatures reached 80 °C. This work will contribute to developing energy-efficient blockchain-based IoT sensor networks.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Factors Affecting Body Temperature
Factors may include:

