Related Experiment Video
Updated: Jul 20, 2025

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Performance of Panel-Estimated GFR Among Hospitalized Older Adults
Esben Iversen1, Anne Kathrine Bengaard2, Aino Leegaard Andersen1
1Department of Clinical Research, Copenhagen University Hospital Amager and Hvidovre, Hvidovre.
Rationale & Objective:
Older adults represent nearly half of all hospitalized patients and are vulnerable to inappropriate dosing of medications eliminated through the kidneys. However, few studies in this population have evaluated the performance of equations for estimating the glomerular filtration rate (GFR)-particularly those that incorporate multiple filtration markers.
Study Design:
Cross-sectional diagnostic test substudy of a randomized clinical trial.
Setting & Participants:
Adults≥65 years of age presenting to the emergency department of Copenhagen University Hospital Amager and Hvidovre in Hvidovre, Denmark, between October 2018 and April 2021.
Tests Compared:
Measured GFR (mGFR) determined using 99mTc-DTPA plasma clearance compared with estimated GFR (eGFR) calculated using 6 different equations based on creatinine; 3 based on creatinine and cystatin C combined; and 2 based on panels of markers including creatinine, cystatin C, β-trace protein (BTP) and/or β2-microglobulin (B2M).
Outcome:
The performance of each eGFR equation compared with mGFR with respect to bias, relative bias, inaccuracy (1-P30), and root mean squared error (RMSE).
Results:
We assessed eGFR performance for 106 patients (58% female, median age 78.3 years, median mGFR 62.9mL/min/1.73m2). Among the creatinine-based equations, the 2009 CKD-EPIcr equation yielded the smallest relative bias (+4.2%). Among the creatinine-cystatin C combination equations, the 2021 CKD-EPIcomb equation yielded the smallest relative bias (-3.4%), inaccuracy (3.8%), and RMSE (0.139). Compared with the 2021 CKD-EPIcomb, the CKD-EPIpanel equation yielded a smaller RMSE (0.136) but larger relative bias (-4.0%) and inaccuracy (5.7%).
Limitations:
Only White patients were included; only a subset of patients from the original clinical trial underwent GFR measurement; and filtration marker concentration can be affected by subclinical changes in volume status.
Conclusions:
The 2009 CKD-EPIcr, 2021 CKD-EPIcomb, and CKD-EPIpanel equations performed best and notably outperformed their respective full-age spectrum equations. The addition of cystatin C to creatinine-based equations improved performance, while the addition of BTP and/or B2M yielded minimal improvement.
Funding:
Grants from public sector industry (Amgros I/S) and government (Capital Region of Denmark).
Trial Registration:
Registered at ClinicalTrials.gov with registration number NCT03741283.
Plain-Language Summary:
Inaccurate kidney function assessment can lead to medication errors, a common cause of hospitalization and early readmission among older adults. Several novel methods have been developed to estimate kidney function based on a panel of kidney function markers that can be measured from a single blood sample. We evaluated the accuracy of these new methods (relative to a gold standard method) among 106 hospitalized older adults. We found that kidney function estimates combining 2 markers (creatinine and cystatin C) were highly accurate and noticeably more accurate than estimates based on creatinine alone. Estimates incorporating additional markers such as β-trace protein and β2-microglobulin did not further improve accuracy.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...
Serum Studies: Renal Function Tests
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...