Evaluation of morphological changes based on cone beam CT for adaptive radiotherapy
Souleyman Slimani1, Zineedine Bouraoui2, Mohammed Anis Ferhati2
1Radiotherapy department, HCA Hospital, Algeria; SNIRM laboratory, Faculty of Physics, University of Sciences and Technology Houari Boumediene, Algeria.
Background:
During radiotherapy treatment, morphological changes can occur in patients (as weight loss). This can lead to significant dosimetric consequences on target volumes and/or organs at risk. The process of adaptive radiotherapy can compensate for these variations. Its deployment in the clinic is slowed by the considerable additional workload for the medical teams. The need for a tool facilitating the detection of patients whose treatment plans need adaptation has been clearly expressed in clinical practice, hence the usefulness of studying the impact of these morphological changes before the decision of adaptive radiotherapy.
Methods:
We considered the cases of 26 patients treated for pelvic cancer where CBCT (Cone Beam Computed Tomography) repositioning images were used. These images have undergone pre-processing to improve their quality and obtain a more precise registration using seven algorithms. We compared the results obtained in order to choose the most adequate algorithm allowing the calculation of external morphological differences using similarity metrics, such as DSC, NCC, MI and TC.
Results:
In this study, we showed that the "rigid body" algorithm, based on the rigid registration, gives the best results. The conservation of external contours allowed quantification of the variation in the external volumes of the patients. The obtained variations were on average (6.12±1.69)% and (4.36±1.22)% for rectum and prostate cancers, respectively.
Conclusion:
Morphological changes evaluated in this study may influence the quality of patient treatment; hence the need for adaptive radiotherapy to take these variations into consideration. However, a rigorous evaluation of the dosimetric impact of these morphological variations is necessary to determine decision criteria for treatment plan adaptation.