Study on the calibration of full polarization imager
Tianquan Liang1, Qingxin Tang1, Quanzhou Yu1
1School of Geography and Environment, Liaocheng University, Liaocheng 252059, PR China.
Abstract:
Polarization is one of the fundamental properties of light, which has a wide range of applications and is developing rapidly. To meet the needs of polarization detection, different types of polarization instruments came into being. The precision of the polarization detection instruments is vital to the result analysis. In this paper, a full polarization imager is designed, and the radiometric calibration and polarization calibration of this instrument are studied. In radiometric calibration, the different numbers lights are set to verify the light intensity response of the imager. The mathematical model was constructed for numerical fitting, and the correlation between the fitted values and the measured values in the 490 nm, 550 nm, and 670 nm bands was above 0.99. Fixed the radiance of the integrating sphere, and adjusted exposure times. The correlation of the three bands is above 0.99, which verifies that the radiative stability of the imager is good. The polarimetric calibration system adopts the adjustable degree of polarization reference light source (APOL). The theoretical and measured values of the degree of polarization of reference light sources in three different bands are analyzed. The results show that the measurement accuracy of the 490 nm band is less than 2%. The precision of polarization measurement in the 550 nm band is less than 1.5%, and the precision of polarization calibration in the 670 nm band is less than 1%. The imager is verified to have high polarization calibration accuracy and meets the requirements of high-precision polarization detection.
More Related Videos
11:57Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
00:07A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
Published on: September 5, 2019
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Correlation Coefficient
IR Spectrometers
Flame Photometry: Lab