Related Experiment Video
Updated: Jul 20, 2025

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Update on Transcatheter Device Closure of Congenital Septal Defects
Kathleen P Wood1, Gregory A Fleming1, Reid C Chamberlain2
1Division of Pediatric Cardiology, Duke University, Durham, USA.
Purpose Of Review:
The goal of this paper is to review currently available devices for closure of atrial septal defects (ASDs) and ventricular septal defects (VSDs).
Recent Findings:
Favorable results from the ASSURED trial resulted in FDA approval for the most recently developed device for transcatheter ASD closure in the United States. Further studies are required to assist in the development or approval of safe devices for transcatheter perimembranous VSD closure in pediatric patients. Device closure is the less invasive and preferred management option for many ASDs, with multiple studies demonstrating lower complication rates, shorter hospital stays, and lower mortality than surgical repair. Complex ASDs that make device closure more difficult include large defects, rim deficiencies, fenestrated defects, multiple defects, and the presence of pulmonary arterial hypertension. Device closure has also become an accepted alternative to surgery for some types of ventricular septal defects VSDs, though challenges and limitations remain. Future innovations including novel devices and techniques are needed to further expand on the types of defects that can be safely closed via transcatheter approach.
More Related Videos
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Regurgitation III: Medical Management
Mitral Stenosis I: Introduction