Serum neurofilament light chain reference database for individual application in paediatric care: a retrospective

Ahmed Abdelhak1, Franziska Petermeier2, Pascal Benkert3

  • 1UCSF Weill Institute for Neurosciences, Department of Neurology, University of California San Francisco, San Francisco, CA, USA.

The Lancet. Neurology
|July 31, 2023
PubMed

Insights

This study established age-adjusted reference values for serum neurofilament light chain (sNfL), a marker of neuroaxonal injury, in healthy children and adolescents. The new sNfL Z scores improve the assessment of neurological conditions in pediatric patients.

Area of Science:

  • Neurology
  • Biomarkers
  • Pediatrics

Background:

  • Neurological conditions are a major cause of childhood disability globally.
  • Serum neurofilament light chain (sNfL) is a specific biomarker for neuroaxonal injury.
  • Establishing age-adjusted sNfL reference values is a research priority for managing pediatric neurological conditions.

Purpose of the Study:

  • To create an age-adjusted sNfL reference range database for healthy children and adolescents.
  • To validate the clinical applicability of this database in pediatric patients with neurological disorders.

Main Methods:

  • sNfL concentrations were measured in 2667 healthy children/adolescents (0-22 years) from European and North American cohorts.
  • Linear models and generalized additive models were used to establish age- and weight-adjusted sNfL reference percentiles and Z scores.
  • The reference dataset's utility was validated in 220 pediatric patients with various neurological conditions.

Main Results:

  • A reference database for sNfL was generated for ages 0-22 years, showing a decrease with age until ~10 years.
  • Weight had a marginal effect on sNfL concentrations independent of age.
  • Age-adjusted sNfL Z scores were significantly higher in pediatric patients with neurological conditions compared to healthy controls, with larger effect sizes than raw sNfL values.

Conclusions:

  • Normative sNfL values in children and adolescents provide a basis for clinical use.
  • sNfL Z scores offer a more accurate assessment of neuroaxonal damage extent in pediatric patients compared to absolute sNfL values.