Related Experiment Video
Updated: Aug 3, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Impact of matrix systems on proximal contact tightness and surface geometry in class II direct composite restoration
Zeinab Omar Tolba1, Ezzat Oraby2, Possy Moustafa Abd El Aziz3
1Conservative Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, Egypt. zeinab.omar@dentistry.cu.edu.eg.
Background:
Poor contact tightness and contour in class II composite restorations are significant problems in clinical practice. They affect occlusal stability and periodontal health. The aim of this study was to evaluate proximal contact tightness and contour established after completing class II direct composite restorations using two pre-contoured matrix systems.
Methods:
Standardized mesio-occlusal cavities were prepared in twenty typodont lower right first permanent molar teeth. Prepared teeth were randomly divided into two groups according to matrix system: Group 1, Sectional matrix system with a separation ring (Palodent V3); and Group 2, Circumferential matrix system with integrated tightener (Palodent 360). Contact tightness was evaluated using universal testing machine. Area, depth and curvature radius of proximal surface concavity in the restoration were evaluated using contact stylus profilometer. T-test was used for comparison between groups.
Results:
Sectional matrix showed higher contact tightness than circumferential matrix system. The results of proximal surface concavity in the restoration showed significantly higher area and depth of concavity with lower radius of curvature in circumferential matrix compared to sectional matrix.
Conclusions:
The use of separation ring with sectional matrix provides superior contact tightness compared to circumferential matrix. However, both matrix systems presented some deficiency regarding proximal contour of direct class II resin composite restoration.
More Related Videos
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Moments of Inertia for Composite Areas
The second moment of area, also known as the moment of inertia, measures a structure's resistance to bending. It is calculated by...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Stress Concentrations
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...