Related Experiment Video
Updated: Jul 20, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Real-time detection of isoprene marker gas based on micro-integrated chromatography system with GOQDs-modifiedμGC
Baoqing Han1,2, Xinyu Zhang1, Yan Wang3
1School of Mechano- Electronic Engineering, Xidian University, Xi'an 710071, People's Republic of China.
Abstract:
Isoprene is a typical physiological marker that can be used to screen for chronic liver disease. This work developed a portable micro-integrated chromatography analysis system based on micro-electromechanical system technology, nanomaterials technology and embedded microcontroller technology. The system integrated components such as graphene oxide quantum dots modified semi-packed microcolumn, In2O3nanoflower (NF) gas-sensitive detector and 3D printed miniature solenoid valve group. The effectiveness of the separation effect of the micro-integrated system was verified by gas mixture test; the laws of the influence of carrier gas pressure and column temperature on the chromatographic separation performance, respectively, were investigated, and the working conditions (column temperature 90 °C and carrier gas pressure 7.5 kPa) for system testing were determined. The percentages of relative standard deviation of the peak areas and retention times obtained for the separated gases were in the range of 0.95%-6.06%, indicating the good reproducibility of the system. Meanwhile, the microintegrated system could detect isoprene down to 50 ppb at small injection volume (1 ml). The system response increased with increasing isoprene concentration and was linearly correlated with isoprene concentration (R2= 0.986), indicating that the system was expected to be used for trace detection of isoprene, a marker gas for liver disease, in the future.
More Related Videos
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...