Related Experiment Video
Updated: Jul 20, 2025

Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
Flexible electrode-based voltammetric detection of Y (III) ions in real water samples using an efficient CyDTA
Yao Liu1, Qiang Xue1, Zeyu Liu1
1MOE Key Laboratory of Groundwater Circulation and Environmental Evolution, School of Water Resources and Environment, China University of Geosciences (Beijing), Beijing 100083, PR China; Beijing Key Laboratory of Water Resources and Environmental Engineering, School of Water Resources and Environment, China University of Geosciences (Beijing), Beijing 100083, PR China.
Abstract:
The rapid detection of rare earth elements is crucial in various fields, such as materials science, biomedicine, and water quality assessment. However, no studies have reported on the detection of yttrium (Y) using electrochemical sensor-based devices. In this study, we present an innovative method for detecting Y(III) ions in aquatic environments using an electroanalytical detection platform. We have developed a complexation catalytic method that integrates trans-1,2-cyclohexanediaminetetraacetic acid (CyDTA) and silver nanoparticles (Ag NPs), thereby enhancing the adsorption and electrochemical response of Y(III) ions. The modified electrode demonstrates an 18-fold increase in the response signal of the Y(III) reduction peak compared to the bare LIG electrode. To elucidate the electrocatalytic mechanism, we conducted various interface characterization methods and DFT simulations. The Ag-CyDTA/LIG electrode exhibits excellent detection performance, with a broad linear dynamic range of 1 × 10-6 to 0.01 g/L and an exceptionally low detection limit of 0.02 μg/L. Significantly, we successfully employed the electrochemical sensing platform to analyze real water samples from rare earth ore, marking the first report on the voltammetric detection of Y(III) ions in real water samples using a flexible electrode. These findings offer a promising technical solution for the practical detection of Y(III) ions.
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
10:48Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Related Concept Videos
Voltammetric Techniques: Cyclic Voltammetry
EDTA: Auxiliary Complexing Reagents
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
EDTA: Chemistry and Properties
Complexometric Titration: Ligands