Related Experiment Video
Updated: Jul 20, 2025

Ion-Exchange Membranes for the Fabrication of Reverse Electrodialysis Device
Published on: July 20, 2021
Effect of electrodialysis on colloidal geometry and dynamics: Why my membrane stack was clogged even after a fine
Wenjing Lu1, Yuchen Du2, Rongqiang Fu3
1College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao 266042, Shandong, China.
Abstract:
As a long-standing problem, electrodialysis (ED) clogging is believed a consequence of colloids. However, its blocking causation and clogging mechanism have not been verified. In this study, electrodialysis was used to treat a colloidal saline solution, aiming to answer the question from the "nature" of ED by investigating the influence of ED parameters such as laminar flow, salt concentration, current density and pH on colloid geometry and dynamics during the desalting process. The results revealed that: (i) laminar and membrane electrostatic repulsion and adsorption could not significantly increase the particle size (maximum 2.28 times), while the applied electric field elevated the particle size by 54.52 times (119.9 ± 13.66 to 6537.5 ± 64.35 nm); (ii) when the initial feed concentration elevated 10 times (0.1 to 1 mol/L NaCl), the particle size upsurged 149-fold (5.99 ± 0.57 to >150 μm), and flocs were generated. This enhancement was mainly attributed to the compressive electric double layer effect, and the Debye length was trimmed from 0.96 to 0.30 nm; (iii) The low current density (25 A/m2) had a profound aggregation effect on small BSA particles (roughly 10 nm); (iv) The change of pH causes the conformational transition of BSA. In the strong acidic (pH = 3.0) environment, the colloidal particle size expanded by 13 times. This study confirmed that the aggregation of colloids was the culprit of spacer clogging during electrodialysis at higher salt concentrations (>1 mol/L). Furthermore, experimental data were substituted into the simulation formula to summarise the geometry and dynamic variation of BSA in ED.
More Related Videos
Related Concept Videos
Dialysis
Coagulation
Colloidal precipitates
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
Detergent Purification of Membrane Proteins
Colloids