Related Experiment Video
Updated: Jul 20, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
"Single-use peripheral" vs "conventional" reaming in total hip arthroplasty: how to respect native centre of rotation
Edoardo Viglietta1, Leonardo Previ2, Veronica Giuliani2
1Orthopaedic Unit, S. Andrea Hospital, University of Rome, "La Sapienza" Via Di Grottarossa 1035, Rome, Italy. edoardo.viglietta.93@gmail.com.
Purpose:
The respect of native hip offset represents a mainstay for satisfying results in total hip arthroplasty (THA). Historically, a great interest has been focused on restoration of femoral offset, while only in recent years, acetabular offset (AO) has been considered. The purpose of the current study was to compare the "single-use peripheral" reaming technique with the "conventional" one for the maintenance of the native COR of the hip and AO in patients undergoing to primary THA.
Methods:
Eighty patients affected from primary hip osteoarthritis were prospectively enrolled in the study and were divided in two groups (Group A "single-use peripheral" and Group B "conventional" reaming technique). Pre- and post-operatively, AO, acetabular floor distance (AFd) and acetabular version (AV) were assessed through a CT scan. A comparison between groups for the radiological parameters, surgical time and complications was performed.
Results:
The demographic data were similar in both groups. The complications rate and the AV did not differ statistically between groups. Group A presented a statistically significant shorter surgical time and lower variation between pre- and post-operative AO and AFd. Statistical significance was defined as p < 0.05.
Conclusions:
The "single-use peripheral" reaming technique demonstrated to be more reliable in reproducing the native COR and AO of patients undergoing to primary THA than the "conventional" one. The operative time was significantly reduced, and it may lead to a reduction in the infection risk even though it was not observed in the current study. Further research could be useful to validate such findings and to assess clinical impact and long-term survival of the implant.
More Related Videos
07:45The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022