Related Experiment Video
Updated: Jul 20, 2025

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Association of Arterial Tortuosity with Hemodynamic Parameters-A Computational Fluid Dynamics Study
Kornelia M Kliś1, Dominika Wójtowicz2, Borys M Kwinta1
1Department of Neurosurgery and Neurotraumatology, Jagiellonian University Medical College, Kraków, Poland.
Background:
Tortuosity of intracranial arteries has been proven to be associated with the risk of intracranial aneurysm development. We decided to analyze which aspects of tortuosity are correlated with hemodynamics parameters promoting intracranial aneurysm development.
Methods:
We constructed 73 idealized models of tortuous artery (length: 25 mm, diameter: 2.5 mm) with single bifurcation. For each model, on the course of segment before bifurcation, we placed 1-3 angles with measures 15, 30, 45, 60, or 75 degrees and arc lengths 2, 5, 7, 10, or 15 mm. We performed computational fluid dynamics analysis. Blood was modeled as Newtonian fluid. We have set velocity wave of 2 cardiac cycles. After performing simulation we calculated following hemodynamic parameters at the bifurcation: time average wall shear stress (TAWSS), time average wall shear stress gradient (TAWSSG), oscillatory shear index (OSI), and relative residence time (RRT).
Results:
We found a significant positive correlation with number of angles and TAWSS (R = 0.329; P < 0.01), TAWSSG (R = 0.317; P < 0.01), and negative with RRT (R = -0.335; P < 0.0.01). Similar results were obtained in terms of arcs lengths. On the other hand, mean angle measure was negatively correlated to TAWSS (R = -0.333; P < 0.01), TAWSSG (R = -0.473 P < 0.01), OSI (R = -0.463; P < 0.01), and positively to RRT (R = 0.332; P < 0.01). On the basis of the obtained results, we developed new tortuosity descriptor, which considered angle measures normalized to its arc length and distance from bifurcation. For such descriptor we found strong negative correlation with TAWSS (R = -0.701; P < 0.01), TAWSSG (R = 0.778; P < 0.01), OSI (R = -0.776; P < 0.01), and positive with RRT (R = 0.747; P < 0.01).
Conclusions:
Hemodynamic parameters promoting aneurysm development are correlated with larger number of smaller angles located on larger arcs.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
09:23Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension
Published on: February 11, 2017
Related Concept Videos
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Laminar and Turbulent Flow