Related Experiment Video
Updated: Jul 20, 2025

Ex Vivo Porcine Experimental Model for Studying and Teaching Lung Mechanics
Published on: April 19, 2024
[Development and validation of a mechanical power-oriented nomogram model for predicting the risk of weaning failure
Yao Yan1, Yongpeng Xie2, Jiye Luo2
1Department of Critical Care Medicine, the Second People's Hospital of Lianyungang City, Lianyungang 222000, Jiangsu, China.
Objective:
To develop and validate a mechanical power (MP)-oriented nomogram prediction model of weaning failure in mechanically ventilated patients.
Methods:
Patients who underwent invasive mechanical ventilation (IMV) for more than 24 hours and were weaned using a T-tube ventilation strategy were collected from the Medical Information Mart for Intensive Care-IV v1.0 (MIMIC-IV v1.0) database. Demographic information and comorbidities, respiratory mechanics parameters 4 hours before the first spontaneous breathing trial (SBT), laboratory parameters preceding the SBT, vital signs and blood gas analysis during SBT, length of intensive care unit (ICU) stay and IMV duration were collected and all eligible patients were enrolled into the model group. Lasso method was used to screen the risk factors affecting weaning outcomes, which were included in the multivariate Logistic regression analysis. R software was used to construct the nomogram prediction model and build the dynamic web page nomogram. The discrimination and accuracy of the nomogram were assessed by receiver operator characteristic curve (ROC curve) and calibration curves, and the clinical validity was assessed by decision curve analysis (DCA). The data of patients undergoing mechanical ventilation hospitalized in ICU of the First People's Hospital of Lianyungang City and the Second People's Hospital of Lianyungang City from November 2021 to October 2022 were prospectively collected to externally validate the model.
Results:
A total of 3 695 mechanically ventilated patients were included in the model group, and the weaning failure rate was 38.5% (1 421/3 695). Lasso regression analysis finally screened out six variables, including positive end-expiratory pressure (PEEP), MP, dynamic lung compliance (Cdyn), inspired oxygen concentration (FiO2), length of ICU stay and IMV duration, with coefficients of 0.144, 0.047, -0.032, 0.027, 0.090 and 0.098, respectively. Logistic regression analysis showed that the six variables were all independent risk factors for predicting weaning failure risk [odds ratio (OR) and 95% confidence interval (95%CI) were 1.155 (1.111-1.200), 1.048 (1.031-1.066), 0.968 (0.963-0.974), 1.028 (1.017-1.038), 1.095 (1.076-1.113), and 1.103 (1.070-1.137), all P < 0.01]. The MP-oriented nomogram prediction model of weaning failure in mechanically ventilated patients showed accurate discrimination both in the model group and external validation group, with area under the ROC curve (AUC) and 95%CI of 0.832 (0.819-0.845) and 0.879 (0.833-0.925), respectively. Furthermore, its predictive accuracy was significantly higher than that of individual indicators such as MP, Cdyn, and PEEP. Calibration curves showed good correlation between predicted and observed outcomes. DCA indicated that the nomogram model had high net benefits, and was clinically beneficial.
Conclusions:
The MP-oriented nomogram prediction model of weaning failure accurately predicts the risk of weaning failure in mechanical ventilation patients and provides valuable information for clinicians making decisions on weaning.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:

