Related Experiment Video
Updated: Jul 19, 2025

05:31
Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
2.9K
Percutaneous Treatment of an Aorto-Right Ventricular Fistula Following Balloon-Expandable Transcatheter Aortic Valve
Cameron Dowling1,2, Christiane Haeffele1, Brian P Pogatchnik3
1Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, California, USA.
JACC. Case Reports
|August 7, 2023
Abstract:
We present the case of a 71-year-old man who experienced congestive cardiac failure after transcatheter aortic valve replacement with a balloon-expandable transcatheter heart valve. Echocardiography and cardiac computed tomography demonstrated an aorto-right ventricular fistula, and successful percutaneous closure was performed with a vascular plug. (Level of Difficulty: Advanced.).