Related Experiment Video
Updated: Jul 19, 2025

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Effect of Gingival Hemostatic Agents on the Surface Detail Reproduction and Dimension Stability of Three Elastomeric
Sirichan Chiaraputt1, Nattida Chokwattanapornchai1, Katanyoo Limchaikul1
1Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Srinakharinwirot University, Bangkok, Thailand.
Abstract:
This study aimed to evaluate the effects of aluminum chloride based hemostatic agents on the surface detail reproduction and dimension stability. Three impression materials were investigated after contaminated with three commercial astringents with different concentration of aluminum chloride. The specimens from three impression materials were fabricated with a stainless-steel mold that followed the American Dental Association specification no.19. The mold was preliminarily contaminated with three hemostatic agents racestyptine, Dryz, and Expasyl™-and 80 specimens from each impression material-polyvinylsiloxane (PVS), polyether, and polyvinylsiloxane ether (PVSE), were fabricated and subjected to each astringent. The surface detail reproduction was examined using a stereomicroscope at 4x magnification, and the dimensional stability was analyzed at 24 hr with a measuring microscope. The surface detail data were statistically analyzed with Fisher's test at a significance level of 0.05. The dimensional stability data were analyzed using two-way ANOVA and Tukey's test at a significance level of 0.05. Aluminum chloride hemostatic agents can affect the surface detail reproduction of impression materials differently (p < 0.05). Thus, the first null hypothesis was rejected. PVS showed the highest percentage of satisfactory surface detail regardless of the hemostatic agent used in this study. PVSE showed a reduced percentage of satisfactory surface detail when the concentration of aluminum chloride was high. The three hemostatic agents affected the dimensional stability of each material differently (p < 0.05). Therefore, the second null hypothesis was also rejected.
More Related Videos
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024