Infraclavicular, Ultrasound-Guided Percutaneous Approach to the Axillary Artery for Arterial Catheter Placement: A Randomized Trial
Related Experiment Video
Updated: Jul 19, 2025

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Ryszard Gawda1, Maciej Marszalski1, Maciej Piwoda1
1Department of Anesthesiology and Intensive Care, Institute of Medical Sciences, University of Opole, Opole, Poland.
Objectives:
To examine whether an ultrasound-guided infraclavicular cannulation of the axillary artery is noninferior to an ultrasound-guided cannulation of the common femoral artery for arterial catheter placement in critically ill patients.
Design:
Prospective, investigator-initiated, noninferiority randomized controlled trial.
Setting:
University-affiliated ICU in Poland.
Patients:
Mechanically ventilated patients with indications for arterial catheter placement.
Interventions:
Patients were randomly assigned into two groups. In the axillary group (A group), an ultrasound-guided infraclavicular, in-plane cannulation of the axillary artery was performed. In the femoral group (F group), an ultrasound-guided, out-of-plane cannulation of the common femoral artery was performed.
Measurements And Main Results:
A total of 1,079 mechanically ventilated patients were screened, of whom 110 were randomized. The main outcome was the cannulation success rate. The secondary outcomes included the artery puncture success rate, the first-pass success rate, number of attempts required to puncture, and the rate of early mechanical complications. The cannulation success rate in the A group and F group was 96.4% and 96.3%, respectively. The lower limit of 95% CI for the difference in cannulation success rate was above the prespecified noninferiority margin of-7% demonstrating noninferiority of infraclavicular approach. No significant differences were found between the groups in terms of puncture success rate and the rate of early mechanical complications.
Conclusions:
An ultrasound-guided infraclavicular cannulation of the axillary artery is noninferior to the cannulation of the common femoral artery in terms of procedure success rate. We found no significant differences in early mechanical complications between the groups.
Related Concept Videos
Arteries of the Upper Limbs
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation