Understanding the barriers to blood pressure assessment in cats
Sarah Ma Caney1, Su Page2, Danièlle A Gunn-Moore3
1Vet Professionals, Geoghegans, 6 Colme Street, Edinburgh, EH3 6AD, UK.
Objectives:
A questionnaire was designed to survey veterinarians and veterinary nurses/technicians on blood pressure (BP) assessment in cats, including ocular examination, encompassing current methodology, indications, uptake and barriers.
Methods:
An online questionnaire was produced and promoted to more than 2000 veterinary professionals, of whom 545 answered all questions and 85 answered most questions.
Results:
Of the participants, 572 (90.8%) were based in the UK and almost all (n = 613, 97.3%) had access to a BP monitor. Of those that had a monitor, most (n = 550, 88.4%) participants had access to a Doppler monitor; 367 (59.0%) participants had access to multiparameter monitors; fewer (n = 202, 32.5%) had access to oscillometric BP monitors. Where applicable, Doppler monitors were most commonly chosen for conscious cat measurements (n = 337, 72.2%) due to the greater 'trust' and 'reliability' of these compared with oscillometric machines. Conscious BP measurement typically involved two members of staff (n = 391, 62.9%). Only 156 (29.1%) participants recommended BP assessment at least several times a week in their interactions with cat owners. BP assessment was routinely recommended in cats with ocular target organ damage (n = 365, 87.7%), chronic kidney disease (n = 346, 78.6%), proteinuria (n = 255, 63.0%) and hyperthyroidism (n = 266, 60.9%). Common equipment-related barriers included 'cuff frustration' and difficulties hearing the pulse signal for Doppler users (72.2% and 71.6%, respectively), and oscillometric machines failing to give a reading at least some of the time (52.8%). Situational hypertension concerns affected many (n = 507, 92.0%), as did lack of time to do the procedure (n = 402, 73.0%). Significant owner barriers included difficulties persuading the owner to bring their cat in for BP checks (n = 475, 86.2%) and concerns over costs (n = 445, 80.8%). Most participants had access to a direct ophthalmoscope (n = 527, 96.5%); however, 399 (73.1%) reported that they struggled to interpret ocular findings.
Conclusions And Relevance:
Significant barriers exist to successful BP assessment in cats. Education and support of clinics should focus on improving confidence with equipment and eye examination.
More Related Videos
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: