Effects of 30% vs. 60% inspired oxygen fraction during mechanical ventilation on postoperative atelectasis: a
Zhaoshun Jiang1,2, Songbin Liu1,2, Lan Wang1
1Department of Anesthesiology, Huadong Hospital Affiliated to Fudan University, Shanghai, China.
Background:
There is the ongoing debate over the effect of inspired oxygen fraction (FiO2) during mechanical ventilation on postoperative atelectasis. We aimed to compare the effects of low (30%) and moderate (60%) FiO2 on postoperative atelectasis. The hypothesis of the study was that 30% FiO2 during mechanical ventilation could reduce postoperative atelectasis volume compared with 60% FiO2.
Methods:
We performed a randomized controlled trial with 120 patients. Subjects were randomly assigned to receive 30% or 60% FiO2 during mechanical ventilation in a 1:1 ratio. The primary outcome was the percentage of postoperative atelectasis volume in the total lung measured using chest CT within 30 min after extubation. The secondary outcomes included different aeration region volumes, incidence of clinically significant atelectasis, and oxygenation index.
Results:
In total, 113 subjects completed the trial, including 55 and 58 subjects in the 30% and 60% FiO2 groups, respectively. The percentage of the postoperative atelectasis volume in the 30% FiO2 group did not differ from that in the 60% FiO2 group. Furthermore, there was no significant difference in the atelectasis volume between the two groups after the missing data were imputed by multiple imputation. Additionally, there were no significant differences in the volumes of the over-aeration, normal-aeration, and poor-aeration regions between the groups. No significant differences in the incidence of clinically significant atelectasis or oxygenation index at the end of surgery were observed between the groups.
Conclusions:
Compared with 60% FiO2, the use of 30% FiO2 during mechanical ventilation does not reduce the postoperative atelectasis volume.
Trial Registration:
Chinese Clinical Trial Registry ( http://www.chictr.org.cn ). Identifier: ChiCTR1900021635. Date: 2 March 2019. Principal invetigator: Weidong Gu.
More Related Videos
05:51Author Spotlight: Unraveling the Impact of Mechanical Ventilation on Diaphragm Function and Patient Outcomes
Published on: November 3, 2023
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: