Improved "nonisolated-sensor" solid polystyrene calorimeter.

L Zeitz, K Ulin, R Caley

    Medical Physics
    |May 1, 1986
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    From confusion to acceptance: overcoming challenges using a fighting spirit and the power of support - a qualitative study of young adults' experiences in the first year after diagnosis in early onset of chronic inflammatory joint disease.

    Scandinavian journal of rheumatology·2025
    Same author

    A method for checking high dose rate treatment times for vaginal applicators.

    Journal of applied clinical medical physics·2001
    Same author

    Clinically evident fat necrosis in women treated with high-dose-rate brachytherapy alone for early-stage breast cancer.

    International journal of radiation oncology, biology, physics·2001
    Same author

    Cosmetic outcome in patients receiving an interstitial implant as part of breast-conservation therapy.

    Radiology·1999
    Same author

    A technique for accurate planning of stereotactic brain implants prior to head ring fixation.

    International journal of radiation oncology, biology, physics·1997
    Same author

    Factors determining outcome in patients treated with interstitial implantation as a radiation boost for breast conservation therapy.

    International journal of radiation oncology, biology, physics·1997
    Same journal

    Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

    Medical physics·2026
    Same journal

    Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

    Medical physics·2026
    Same journal

    Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

    Medical physics·2026
    Same journal

    Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

    Medical physics·2026
    Same journal

    Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

    Medical physics·2026
    Same journal

    Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

    Medical physics·2026
    See all related articles

    A novel solid polystyrene calorimeter achieves high precision (less than 0.3%) for absorbed dose measurements. Its accuracy was validated against ionization chambers, showing excellent agreement for cobalt-60 gamma-ray dosimetry.

    Area of Science:

    • Medical Physics
    • Radiation Dosimetry
    • Calorimetry

    Background:

    • Accurate absorbed dose determination is crucial for radiation therapy and research.
    • Existing dosimetry methods have limitations in precision and accuracy.
    • Solid calorimeters offer a potential alternative for precise dose measurements.

    Purpose of the Study:

    • To describe a nonisolated-sensor solid polystyrene calorimeter for absorbed dose measurements.
    • To evaluate the precision and accuracy of the developed calorimeter.
    • To compare calorimeter measurements with established ionization dosimetry protocols.

    Main Methods:

    • Development of a solid polystyrene calorimeter with a nonisolated sensor.
    • Measurement of absorbed dose in a cobalt-60 (60Co) gamma-ray field.

    Related Experiment Videos

  • Comparison of calorimeter data with ionization chamber measurements using the AAPM TG-21 protocol.
  • Long-term stability assessment of the calorimeter over 247 days.
  • Main Results:

    • The polystyrene calorimeter achieved a precision of less than 0.3% (standard error of the mean).
    • Absorbed dose measurements agreed within 1.5% with ionization chamber results in a polystyrene phantom.
    • Long-term measurements showed good agreement with expected values based on 60Co decay.
    • The calorimeter system integrates computer-aided data acquisition, storage, and analysis.

    Conclusions:

    • The developed solid polystyrene calorimeter provides a precise and accurate method for absorbed dose determination.
    • This calorimeter is a viable tool for dosimetry applications, particularly in 60Co gamma-ray fields.
    • The system's advanced data processing capabilities enhance its utility in radiation physics research.