Related Experiment Video
Updated: Jul 19, 2025

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Ultrasound assessment of endotracheal tube depth in neonates: a prospective feasibility study
Orly Levkovitz1, Dana Schujovitzky2, Rodica Stackievicz3
1Department of Neonatology, Meir Medical Center, Kfar Saba, Israel orly.levko@gmail.com.
Objective:
To examine the reliability of a novel ultrasound (US) method for assessment of endotracheal tube (ETT) position in neonates.
Design:
Prospective, observational, single-centre, feasibility study.
Setting:
Level III neonatal intensive care unit.
Patients:
Term and preterm neonates requiring endotracheal intubation.
Intervention:
US measurement of the ETT tip to right pulmonary artery (RPA) distance was used to determine ETT position according to one-fourth to three-fourths estimated tracheal length for weight. US demonstration of pleural sliding and diaphragmatic movement was also assessed. Chest radiography (CXR) was performed following each intubation.
Main Outcome Measures:
Agreement between US assessment of ETT tip position and CXR served as the gold standard. Sensitivity, specificity, positive and negative predictive values for each US method and correlation between ETT tip to RPA distance on US, and ETT tip to carina distance on CXR were assessed.
Results:
Forty-two US studies were performed on 33 intubated neonates. US evaluation of ETT-RPA distance identified 100% of ETTs positioned correctly: 77% deep and 80% high, demonstrating strong agreement with CXR (kappa=0.822). Sensitivity was 78%, specificity 100%, positive predictive value 100% and negative predictive value 86%. US ETT-RPA distance strongly correlated with CXR ETT-carina distance (r=0.826). No significant agreement was found between CXR and US assessment of pleural sliding and diaphragmatic movement. No adverse events were encountered during US scans.
Conclusion:
US evaluation of ETT-RPA distance demonstrated excellent accuracy for determining ETT position in neonates compared with CXR. More research is needed to support its feasibility in clinical settings.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...