Related Experiment Video
Updated: Jul 19, 2025

A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Thermophysiological aspects of wearable robotics: Challenges and opportunities
1School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, US.
Abstract:
Technological advancements in the last two decades have enabled development of a variety of mechanically supporting wearable robots (i.e. exoskeletons) that are transitioning to practice in medical and industrial settings. The feedback from industry and recent controlled studies is highlighting thermal discomfort as a major reason for the disuse of the devices and a substantial barrier to their long-term adoption. Furthermore, a brief overview of the devices and their intended applications reveals that many of the potential users are likely to face thermal comfort issues because of either high exertion or medically related high heat sensitivity. The aim of this review is to discuss these emerging thermal challenges and opportunities surrounding wearable robots. This review discusses mechanisms, potential solutions, and a platform for systematically measuring heat transfer inhibition caused by wearing of an exoskeleton. Lastly, the potential for substantial metabolic rate reduction provided by exoskeletons to reduce worker thermal strain in warm-to-hot conditions is also considered.
Related Concept Videos
Thermoregulation
Thermosensation
Thermal Stress
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...