Progress in detection of and correction for low-energy contamination
Slawomir Domagala1,2, Petrick Nourd1, Kay Diederichs3
1DataQ Intelligence, Fichtelgebirgsstrasse 66, 95448 Bayreuth, Germany.
Abstract:
Contamination with low-energy radiation leads to an increased number of weighted residuals being larger in absolute terms than three standard uncertainties. For a Gaussian distribution, these rare events occur only in 0.27% of all cases, which is a small number for small- to medium-sized data sets. The correct detection of rare events - and an adequate correction procedure - thus relies crucially on correct standard uncertainties, which are often not available [Henn (2019), Crystallogr. Rev. 25, 83-156]. It is therefore advisable to use additional, more robust, metrics to complement the established ones. These metrics are developed here and applied to reference data sets from two different publications about low-energy contamination. Other systematic errors were found in the reference data sets. These errors compromise the correction procedures and may lead to under- or overcompensation. This can be demonstrated clearly with the new metrics. Empirical correction procedures generally may be compromised or bound to fail in the presence of other systematic errors. The following systematic errors, which were found in the reference data sets, need to be corrected for prior to application of the low-energy contamination correction procedure: signals of 2λ contamination, extinction, disorder, twinning, and too-large or too-low standard uncertainties (this list may not be complete). All five reference data sets of one publication show a common resolution-dependent systematic error of unknown origin. How this affects the correction procedure can be stated only after elimination of this error. The methodological improvements are verified with data published by other authors.
Related Concept Videos
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
High-Performance Liquid Chromatography: Types of Detectors