Related Experiment Video
Updated: Jul 19, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Exhaled CO2 monitoring to guide non-invasive ventilation at birth: a systematic review
Vix Monnelly1, Justin B Josephsen2, Tetsuya Isayama3
1Department of Neonatology, Simpson Centre for Reproductive Health, Royal Infirmary of Edinburgh, Edinburgh, UK.
Objective:
Measuring exhaled carbon dioxide (ECO2) during non-invasive ventilation at birth may provide information about lung aeration. However, the International Liaison Committee on Resuscitation (ILCOR) only recommends ECO2 detection for confirming endotracheal tube placement. ILCOR has therefore prioritised a research question that needs to be urgently evaluated: 'In newborn infants receiving intermittent positive pressure ventilation by any non-invasive interface at birth, does the use of an ECO2 monitor in addition to clinical assessment, pulse oximetry and/or ECG, compared with clinical assessment, pulse oximetry and/or ECG only, decrease endotracheal intubation in the delivery room, improve response to resuscitation, improve survival or reduce morbidity?'.
Design:
Systematic review of randomised and non-randomised studies identified by Ovid MEDLINE, Embase and Cochrane CENTRAL search until 1 August 2022.
Setting:
Delivery room.
Patients:
Newborn infants receiving non-invasive ventilation at birth.
Intervention:
ECO2 measurement plus routine assessment compared with routine assessment alone.
Main Outcome Measures:
Endotracheal intubation in the delivery room, response to resuscitation, survival and morbidity.
Results:
Among 2370 articles, 23 were included; however, none had a relevant control group. Although studies indicated that the absence of ECO2 may signify airway obstruction and ECO2 detection may precede a heart rate increase in adequately ventilated infants, they did not directly address the research question.
Conclusions:
Evidence to support the use of an ECO2 monitor to guide non-invasive positive pressure ventilation at birth is lacking. More research on the effectiveness of ECO2 measurement in addition to routine assessment during non-invasive ventilation of newborn infants at birth is needed.
Prospero Registration Number:
CRD42022344849.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: