Related Experiment Video
Updated: Jul 19, 2025

Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization
Published on: March 3, 2023
Patient Positioning Assistive Technology Applicable to the Existing Computed Tomography System: Estimation by Pixel
Atsushi Urikura, Yosuke Miyauchi1, Tsukasa Yoshida1
1From the Division of Diagnostic Radiology, Shizuoka Cancer Center, Shizuoka.
Abstract:
This study aimed to propose a patient positioning assistive technique using computed tomography (CT) scout images. A total of 210 patients who underwent CT scans in a single center, including on the upper abdomen, were divided into a study set of 127 patients for regression and 83 patients for verification. Linear regression analysis was performed to determine the R2 coefficient and the linear equation related to the mean pixel value of the scout image and ideal table height (TH ideal ). The average pixel values of the scout image were substituted into the regression equation to estimate the TH ideal . To verify the accuracy of this method, the distance between the estimated table height (TH est ) and TH ideal was measured. The medians of age (in years), gender (male/female), height (in centimeters), and body weight (in kilograms) for the regression and verification groups were 68 versus 70, 85/42 versus 55/28, 163.8 versus 163.0, and 59.9 versus 61.9, respectively. Linear regression analysis indicated a high coefficient of determination ( R2 = 0.91) between the mean pixel value of the scout image and TH ideal . The correlation coefficient between TH ideal and TH est was 0.95 (95% confidence interval, 0.92-0.97; P < 0.0001), systematic bias was 0.2 mm, and the limits of agreement were -5.4 to 5.9 ( P = 0.78). The offset of the table height with TH est was 2.8 ± 2.1 mm. The proposed estimation method using scout images could improve the automatic optimization of table height in CT, and it can be used as a general-purpose automatic positioning technique.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...