Related Experiment Video
Updated: Jul 19, 2025

Ex Vivo Porcine Experimental Model for Studying and Teaching Lung Mechanics
Published on: April 19, 2024
Perioperative lung function following flow controlled ventilation for robot-assisted prostatectomies in steep
Mustafa Syrafe1, Wiebke Köhne1, Andre Börgers1
1Department of Anaesthesia, Critical Care Medicine and Pain Therapy, Kliniken Essen-Mitte, Henricistr. 92, 45136, Essen, Germany.
Background:
Steep Trendelenburg position combined with capnoperitoneum can lead to pulmonary complications and prolonged affection of postoperative lung function. Changes in pulmonary function occur independent of different modes of ventilation and levels of positive end-expiratory pressure (PEEP). The effect of flow-controlled ventilation (FCV) has not been evaluated yet. We perioperatively measured spirometric lung function parameters in patients undergoing robot-assisted prostatectomy under FCV. Our primary hypothesis was that there is no significant difference in the ratio of the maximal mid expiratory and inspiratory flow (MEF50/MIF50) after surgery.
Methods:
In 20 patients, spirometric measurements were obtained preoperatively, 40, 120, and 240 min and 1 and 5 days postoperatively. We measured MEF50/MIF50, vital capacity (VC), forced expiratory volume in 1 s (FEV1), and intraoperative ventilation parameters.
Results:
MEF50/MIF50 ratio increased from 0.92 (CI 0.73-1.11) to 1.38 (CI 1.01-1.75, p < 0.0001) and returned to baseline within 24 h, while VC and FEV1 decreased postoperatively with a second nadir at 24 h and only normalized by the fifth day (p < 0.0001). Compared to patients with PCV, postoperative lung function changes similarly.
Conclusion:
Flow-controlled ventilation led to changes in lung function similar to those observed with pressure-controlled ventilation. While the ratio of MEF50/MIF50 normalized within 24 h, VC and FEV1 recovered within 5 days after surgery.
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...