Related Experiment Video
Updated: Jul 19, 2025

Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems
Published on: May 2, 2025
A pressure monitoring approach for pressure ulcer prevention
Bethel Osuagwu1,2, Euan McCaughey3,4,5, Mariel Purcell3,4
1Biomedical Engineering Research Division, School of Engineering, University of Glasgow, Glasgow, UK. bethel.osuagwu@glasgow.ac.uk.
Background:
A pressure ulcer (PU) is a debilitating condition that disproportionately affects people with impaired mobility. PUs facilitate tissue damage due to prolonged unrelieved pressure, degrading quality of life with a considerable socio-economic impact. While rapid treatment is crucial, an effective prevention strategy may help avoid the development of PUs altogether. While pressure monitoring is currently used in PU prevention, available monitoring approaches are not formalised and do not appropriately account for accumulation and relief of the effect of an applied pressure over a prolonged duration. The aim of this study was to define an approach that incorporates the accumulation and relief of an applied load to enable continuous pressure monitoring.
Results:
A tunable continuous pressure magnitude and duration monitoring approach that can account for accumulated damaging effect of an applied pressure and pressure relief over a prolonged period is proposed. Unlike classic pressure monitoring approaches, the presented method provides ongoing indication of the net impact of a load during and after loading.
Conclusions:
The tunable continuous pressure magnitude and duration monitoring approach proposed here may further development towards formalised pressure monitoring approaches that aim to provide information on the risk of PU formation in real-time.
Related Concept Videos
Peripheral Artery Disease IV: Nursing Management
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

