Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Hearing aid fitting: analysis of the impact on the auditory system during the first year of use in moderate and severe hearing loss.

CoDAS·2026
Same author

Extraction, analysis and presentation of results in a scoping review in Brazilian nursing: scoping review.

Revista latino-americana de enfermagem·2026
Same author

Factors associated with orofacial myofunctional condition in patients with temporomandibular disorder and somatosensory tinnitus.

Journal of applied oral science : revista FOB·2026
Same author

Relationship between the impact of tinnitus and craniofacial and cervical disability, dizziness, and emotional symptoms in individuals with temporomandibular disorders.

Cranio : the journal of craniomandibular practice·2026
Same author

Actions on childhood voice in public schools: a scoping review.

CoDAS·2026
Same author

Prevalence of systemic complications of COVID-19 in critically ill patients: systematic review with meta-analysis.

Revista latino-americana de enfermagem·2025

Related Experiment Video

Updated: Jul 19, 2025

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
06:04

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages

Published on: March 24, 2023

420

The P300 Auditory Evoked Potential in Cochlear Implant Users: A Scoping Review.

Maria Stella Arantes do Amaral1, Nelma Ellen Zamberlan-Amorin2, Karina Dal Sasso Mendes3

  • 1Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, Hospital das Clínicas, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, São Paulo, SP, Brazil.

International Archives of Otorhinolaryngology
|August 11, 2023
PubMed
Summary

P300 auditory evoked potentials reveal altered neural processing in cochlear implant (CI) users, showing longer P300 latency and smaller amplitude. These findings highlight the need for controlled P300 protocols in CI diagnostics and monitoring.

Keywords:
audiologyauditory evoked potentialcochlear implantelectrophysiologyneuronal plasticity

More Related Videos

Assessment of Audio-Tactile Sensory Substitution Training in Participants with Profound Deafness Using the Event-Related Potential Technique
11:39

Assessment of Audio-Tactile Sensory Substitution Training in Participants with Profound Deafness Using the Event-Related Potential Technique

Published on: September 7, 2022

2.2K
Performing Intracochlear Electrocochleography During Cochlear Implantation
09:10

Performing Intracochlear Electrocochleography During Cochlear Implantation

Published on: March 8, 2022

4.4K

Related Experiment Videos

Last Updated: Jul 19, 2025

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
06:04

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages

Published on: March 24, 2023

420
Assessment of Audio-Tactile Sensory Substitution Training in Participants with Profound Deafness Using the Event-Related Potential Technique
11:39

Assessment of Audio-Tactile Sensory Substitution Training in Participants with Profound Deafness Using the Event-Related Potential Technique

Published on: September 7, 2022

2.2K
Performing Intracochlear Electrocochleography During Cochlear Implantation
09:10

Performing Intracochlear Electrocochleography During Cochlear Implantation

Published on: March 8, 2022

4.4K

Area of Science:

  • Neuroscience
  • Audiology
  • Biomedical Engineering

Background:

  • The P300 auditory evoked potential is a key electrophysiological measure reflecting central auditory processing.
  • Cochlear implants (CIs) bypass damaged hair cells, but their impact on neural processing, particularly P300 responses, requires thorough investigation.

Purpose of the Study:

  • To systematically review and synthesize scientific evidence on P300 responses in adult cochlear implant (CI) users.
  • To identify patterns and influencing factors of P300 in CI users compared to typical hearing individuals.

Main Methods:

  • A systematic literature search identified 87 articles, with 20 selected for review.
  • Data synthesis involved analyzing P300 latency and amplitude across studies using various auditory stimuli.
  • Rayyan software was utilized for article screening and data management.

Main Results:

  • CI users consistently demonstrated prolonged P300 latency compared to typical hearing individuals.
  • A significant proportion of studies (35%) reported smaller P300 amplitudes in CI users.
  • Stimulus type influenced P300: speech stimuli were associated with prolonged responses in 60% of studies.

Conclusions:

  • A controlled P300 protocol is crucial for diagnosing and monitoring CI users.
  • Increased P300 latency and decreased amplitude are characteristic findings in CI users, irrespective of stimulus type.