Clinical evaluation of k-space correlation informed motion artifact detection in segmented multi-slice MRI
Ikbeom Jang1,2, Malte Hoffmann1,2, Nalini Singh3,4
1Department of Radiology, Massachusetts General Hospital, Boston, MA, United States.
Abstract:
Motion artifacts can negatively impact diagnosis, patient experience, and radiology workflow especially when a patient recall is required. Detecting motion artifacts while the patient is still in the scanner could potentially improve workflow and reduce costs by enabling immediate corrective action. We demonstrate in a clinical k-space dataset that using cross-correlation between adjacent phase-encoding lines can detect motion artifacts directly from raw k-space in multi-shot multi-slice scans. We train a split-attention residual network to examine the performance in predicting motion artifact severity. The network is trained on simulated data and tested on real clinical data.