Related Experiment Video
Updated: Jul 19, 2025

Author Spotlight: Investigating HR-Dependent Cardiac Function in Mouse Models Through a Novel Atrial-Pacing Approach
Published on: July 21, 2023
Diastolic exercise stress testing in heart failure with preserved ejection fraction: The DEST-HF study
Simon Wernhart1, Annika Goertz1, Juergen Hedderich2
1Department of Cardiology and Vascular Medicine, University Hospital Essen, University Duisburg-Essen, West German Heart and Vascular Center, Essen, Germany.
Aims:
Pulmonary capillary wedge pressure (PAWP) ≥25 mmHg during bicycle ergometry is recommended to uncover occult heart failure with preserved ejection fraction. We hypothesized that PAWP increase would differ in available diastolic stress tests and that the margin of PAWP ≥25 mmHg would only be reliably achieved through ergometry.
Methods And Results:
We conducted a prospective, single-arm study in patients with an intermediate risk for heart failure with preserved ejection fraction according to the ESC HFA-PEFF score. A total of 19 patients underwent four stress test modalities in randomized order: leg raise, fluid challenge, handgrip, and bicycle ergometry. The primary outcome was the difference (Δ) between resting and exercise PAWP in each modality. Secondary outcomes were differences (Δ) in mean pulmonary artery pressure (mPAP), cardiac output (CO), as well as the ratios between mPAP and PAWP to CO. Compared to resting values, passive leg raise (Δ7.7 ± 8.0 mmHg, p = 0.030), fluid challenge (Δ9.2 ± 6.4 mmHg, p = 0.003), dynamic handgrip (Δ9.6 ± 7.5 mmHg, p = 0.002), and bicycle ergometry (Δ22.3 ± 5.0 mmHg, p < 0.001) uncovered increased PAWP during exercise. Amongst these, bicycle ergometry also demonstrated the highest ΔmPAP (27.2 ± 7.1 mmHg, p < 0.001), ΔCO (3.3 ± 2.6 L/min, p < 0.001), ΔmPAP/CO ratio (2.3 ± 2.0 mmHg/L/min, p < 0.001), and ΔPAWP/CO ratio (2.2 ± 1.4 mmHg/L/min, p < 0.001) compared to other modalities. PAWP ≥25 mmHg was only reliably achieved in bicycle ergometry (31.1 ± 3.9 mmHg). In all other modalities only 10.5% of patients achieved PAWP ≥25 mmHg (handgrip 18.4 ± 6.6 mmHg, fluid 18.1 ± 5.6 mmHg, leg raise 16.5 ± 7.0 mmHg).
Conclusions:
We demonstrate that bicycle ergometry exhibits a distinct haemodynamic response with higher increase of PAWP compared to other modalities. This finding needs to be considered for valid detection of exercise PAWP ≥25 mmHg when non-bicycle tests remain inconclusive.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
09:20Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Heart Failure II: Pathophysiology
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Heart Failure IV: Classification and Diagnostic Evaluation