Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

416
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
416
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

616
Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
616
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

478
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
478
Flame Photometry: Lab01:16

Flame Photometry: Lab

275
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
275
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

4.4K
Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
4.4K
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

617
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
617

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Probing Blended-Additive-Regulated Interface Chemistry Based on a Dynamic Competition Mechanism in Lithium Metal Batteries.

Angewandte Chemie (International ed. in English)·2026
Same author

Individualized Bayesian Inference Identifies Novel Genetic Variants for Parkinson's Disease.

Genetic epidemiology·2026
Same author

Bioinspired Anisotropic Collagen-Based Conductive Hydrogels Promote Neuronal Differentiation via Activation of Mechanoelectrical Signaling.

ACS applied bio materials·2026
Same author

Novel Alzheimer's disease-associated variants and genetic interactions identified from UK biobank whole-exome sequencing data using IBI-DT.

Scientific reports·2026
Same author

Nanoassembled SERS Sensing for Complex Biological Systems: From Hotspot Engineering to Interface Regulation.

Accounts of chemical research·2026
Same author

5'-end uridine-derived base modification for siRNAs potency reinforcement.

Cell & bioscience·2026

Related Experiment Video

Updated: Jul 19, 2025

Encapsulating Cytochrome c in Silica Aerogel Nanoarchitectures without Metal Nanoparticles while Retaining Gas-phase Bioactivity
11:06

Encapsulating Cytochrome c in Silica Aerogel Nanoarchitectures without Metal Nanoparticles while Retaining Gas-phase Bioactivity

Published on: March 1, 2016

10.4K

Colorimetric Aerogel Gas Sensor with High Sensitivity and Stability.

Xiaoli Xia1,2, Ruonan Wu2, Lei Zhang2

  • 1Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, School of Chemistry, Xiangtan University, Xiangtan 411105, P. R. China.

Analytical Chemistry
|August 11, 2023
PubMed
Summary

New aerogel sensors made from metal-organic frameworks (MOFs) offer a highly sensitive and stable method for detecting harmful formic acid vapor. This breakthrough improves safety through faster, more reliable gas detection.

More Related Videos

Synthesis Method for Cellulose Nanofiber Biotemplated Palladium Composite Aerogels
11:27

Synthesis Method for Cellulose Nanofiber Biotemplated Palladium Composite Aerogels

Published on: May 9, 2019

8.1K
Nanostructured Ag-zeolite Composites as Luminescence-based Humidity Sensors
07:13

Nanostructured Ag-zeolite Composites as Luminescence-based Humidity Sensors

Published on: November 15, 2016

10.2K

Related Experiment Videos

Last Updated: Jul 19, 2025

Encapsulating Cytochrome c in Silica Aerogel Nanoarchitectures without Metal Nanoparticles while Retaining Gas-phase Bioactivity
11:06

Encapsulating Cytochrome c in Silica Aerogel Nanoarchitectures without Metal Nanoparticles while Retaining Gas-phase Bioactivity

Published on: March 1, 2016

10.4K
Synthesis Method for Cellulose Nanofiber Biotemplated Palladium Composite Aerogels
11:27

Synthesis Method for Cellulose Nanofiber Biotemplated Palladium Composite Aerogels

Published on: May 9, 2019

8.1K
Nanostructured Ag-zeolite Composites as Luminescence-based Humidity Sensors
07:13

Nanostructured Ag-zeolite Composites as Luminescence-based Humidity Sensors

Published on: November 15, 2016

10.2K

Area of Science:

  • Materials Science
  • Chemical Sensing
  • Nanotechnology

Background:

  • Detecting formic acid vapor is crucial for human health and safety.
  • Metal-organic frameworks (MOFs) are promising for gas detection but face challenges in sensitivity and stability.
  • Developing robust MOF-based gas sensors remains a significant hurdle.

Purpose of the Study:

  • To develop a simple and effective method for fabricating MOF-based aerogel sensors.
  • To enhance the sensitivity, response time, and mechanical stability of gas sensors for formic acid detection.
  • To demonstrate the potential of aerogel structures for advanced gas-sensing applications.

Main Methods:

  • Fabrication of colorimetric aerogel sensors using MOF particles through ice template-assisted methods.
  • Design of aerogel sensors with staggered lamellae structures to maximize gas-analyte interactions.
  • Comparative analysis of aerogel sensors against conventional film sensors for formic acid detection.

Main Results:

  • Aerogel sensors exhibited an 8-fold lower limit of detection for formic acid compared to film sensors.
  • Demonstrated 15-fold better sensitivity at low concentrations and a 34-fold faster response time.
  • Aerogel structure provided enhanced mechanical stability and high air-volume intake for efficient gas detection.

Conclusions:

  • The ice template-assisted fabrication of MOF aerogels offers a superior approach for gas sensing.
  • Aerogel sensors provide significantly enhanced performance metrics (sensitivity, speed, stability) for formic acid detection.
  • This method holds great potential for rapid, real-time detection of various target molecules and advanced sensor construction.