Related Experiment Video
Updated: Jul 19, 2025

Determining Viral Disinfection Efficacy of Hot Water Laundering
Published on: June 21, 2022
Fast and Easy Disinfection of Coronavirus-Contaminated Face Masks Using Ozone Gas Produced by a Dielectric Barrier
Jinyeop Lee1, Cheolwoo Bong1, Wanyoung Lim2
1School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea.
Abstract:
During the COVID-19 pandemic, face masks have become limited in stock. Most of sterilization methods are not applicable for eliminating virus from face masks without compromising the filtration efficiency of the masks. In this study, using a human coronavirus (HCoV-229E) as a surrogate for SARS-CoV-2 contamination on KF94 face masks, we show that the virus loses its infectivity with a 4 log reduction when exposed for 10 s to 120 ppm ozone gas produced by a dielectric barrier discharge plasma generator. Scanning electron microscopy, particulate filtration efficiency (PFE), and inhalation resistance tests revealed that there was no detectable structural or functional deterioration observed in the electrocharged filter layer of Korea Filter (KF) 94 masks even after their excessive exposure to ozone. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) showed decreases in amplification efficiency of HCoV-229E RNA recovered from masks exposed to ozone, indicating the damage to the RNA by the ozone treatment. Our results demonstrate that the plasma generator rapidly disinfects contaminated face masks at least five times without compromising filtration efficiency.
More Related Videos
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...

