Related Experiment Video
Updated: Jul 19, 2025

Milk Collection in the Rat Using Capillary Tubes and Estimation of Milk Fat Content by Creamatocrit
Published on: December 16, 2015
Exploring Alternative Methods to Reduce Milk Flow Rate From Infant Bottle Systems: Bottle Angle, Milk Volume, and
Katlyn Elizabeth McGrattan1,2, Gregory Paul Jansen1, Jennifer Meraz Barrera1
1Department of Speech-Language and Hearing Science, University of Minnesota, Twin Cities, Minneapolis.
Purpose:
Modifying milk flow rate is a common pediatric dysphagia treatment. Though past investigations have demonstrated how this can be achieved using bottle nipples, little is known about the impact of other bottle modifications. The objective of this investigation is to demonstrate how bottle vent, bottle position, and volume of milk alter bottle pressures and milk flow.
Method:
A Dr. Brown's bottle filled with formula was secured to a retort stand and inverted to allow milk to free flow from a Level 1 nipple. Milk flow rate and bottle pressures were calculated under three conditions: (a) with and without a vent in place; (b) with varying volumes of milk (1-4 oz); and (c) in horizontal, semi-inverted, and completely inverted positions. Differences between flow rates under the conditions were tested using repeated-measures analysis of variance.
Results:
Upon inversion, milk dripped from both vented and unvented bottles. Dripping continued throughout the 20-min testing period in the vented bottle; however, as air pressure and hydrostatic pressure declined (p < .01) in the unvented bottle, milk flow slowed and eventually ceased (p < .001). As angle of bottle inversion increased, hydrostatic pressure and milk flow rate had corresponding increases as well (p < .001). Hydrostatic pressure increased an average of 1.4 ± 0.12 mm Hg per additional ounce of formula that was added to the bottle, with corresponding increases in milk flow rate observed (p < .001).
Conclusions:
Milk flow rate can be altered by feeding conditions outside of bottle nipples alone. Future work examining the clinical significance of these modifications is warranted to determine optimal interventions.
More Related Videos
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Pipe Flowrate Measurement: Problem Solving
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...

